| HIGH TEMPERATURE AND RUGGED INDUSTRIAL ACCELEROMETERS |
| |
 1060 |
 1061 |
 1070 |
 1074 |
| Acceleration Sensitivity mV/g |
10 |
100 |
100 |
50 to 1000 |
Velocity Sensitivity
mV/mm/sec |
NA |
NA |
10 |
5 to 25 |
| Dynamic Range. g |
±500 |
±50 |
±50 |
±50 |
| Velocity Range mm/sec |
NA |
NA |
50 |
25 |
Acceleration
Frequency Response |
0.9 to 10,000 |
2 to 5,000 |
10 to 3,000 |
2 to 5,000 |
| Velocity Frequency Response |
NA |
NA |
10 to 1,000 |
10 to 1,000 |
| Temperataure Response °C |
-60 to +200
±10% |
-40 to +125
±5% |
-20 to +400
±10% |
-40 to +125
±5% |
Acceleration Limit
(shock - g) |
2,000 |
500 |
500 |
500 |
| Power Requirement Vdc |
+12 to +30 |
+18 to +30 |
+24 to +30 |
+24 to +30 |
Constanct Current
Supply mAdc |
1 to 5 |
1 to 10 |
25 |
1 to 10 |
| Weight grams |
52 |
75 |
500 |
500 |
| Mounting |
M8 Stud or 1/4-28 UNF Stud |
1/4-28 UNF Stud Isolated |
4x4.5mm holes 30mm centres |
4x4.5mm holes 30mm centres |
| Connector |
2 Pin Glass Sealed |
Optional
See notes |
4 Pin 62GB 16J8 45 |
Optional
See notes |
| Cable |
1260-xx |
1261-xx |
1270-xx
see notes |
1274-xx
see notes |
| Dimensions |
 |
 |
 |
 |
|
 |